Auto Tonometer + Corneal Response Technology™ Reichert 7CR, NEW!

Description

Reichert 7CR
Auto Tonometer + Corneal Response Technology™, NEW!

The new Reichert 7CR Auto Tonometer + Corneal Response Technology provides Corneal-Compensated IOP (IOPcc), which is less influenced by biomechanical properties of the cornea than other methods of tonometry. Reichert 7CR is... The Glaucoma Tonometer.

The Glaucoma Tonometer

The Reichert 7CR from Reichert Technologies utilizes a patented bi-directional applanation process to characterize the biomechanical properties of the cornea and reduce their impact on the IOP measurement. This measurement, referred to as Corneal Compensated IOP (IOPcc) is minimally affected by corneal visco-elastic properties, thickness, or surgical procedures such as LASIK or PRK. As such, IOPcc is a better indicator of glaucoma than other methods of tonometry, including Goldmann Applanation.

The Reichert 7CR is more clinically valid in all subjects, including:
• Normal Tension Glaucoma patients

• Primary Open Angle Glaucoma patients

• Post-LASIK and refractive surgery patients

• Patients with Fuchs’ or Corneal Edema

• Keratoconus patients

• Patients with thick, thin, or otherwise biomechanically atypical corneas

Waveform Score ensures reliability of results
The Reichert 7CR employs an advanced signal-scoring feature that helps ensure the accuracy and reliability of measurement results. A score for each measurement is displayed on the screen. Scores below a certain threshold are indicated as unreliable.

Non-Contact measurement methodology
The Reichert 7CR utilizes a collimated air-jet to deform the cornea and an electro-optical system to monitor the applanation process. The result is a rapid measurement that is comfortable and non-intimidating for the patient and simple for any operator to execute. Best of all, the measurement is non-contact so no anesthesia is required and there is no risk of cross contamination.

Automatic, real-time applanation control
The Reichert 7CR applanation detection system monitors the change in corneal curvature in real time, recording 400 data samples during the 25 millisecond measurement process! This unique feature ensures that the appropriate applanation force is automatically delivered to each eye being measured.

User and patient friendly
The all-new touch screen interface features an easy-to-use icon-based operating system enabling even inexperienced users to make measurements in seconds. The full color display guides the operator through the measurement process showing everything from the alignment of the eye, to the display of the readings. Patients simply lean against the forehead rest while the fully automated alignment and measurement takes place.

The speed and simplicity of the Reichert 7CR
are unlike any other tonometer!

Features:
• IOPcc is a better indicator of glaucoma presence, making Reichert 7CR "The Glaucoma Tonometer"

• Alignment is completely automated

• One-touch, triple-measurement mode

• Clearly displays all measurement data

• Internal printer simplifies record keeping

• Electronic data transfer via USB port


Specifications:

Height:
19.75 in (50.2 cm)

Width:
10.5 in (26.7 cm)

Depth:
14 in (35.6 cm)

Weight:
23 lbs (10.4 kg)

Voltage:
100-240 VAC

Frequency:
50/60 Hz

Measurement Range:
7 - 60 mmHg (ISO 8612 tonometer standard)

Please find further technical details in the PDF belonging to this offer.